{"id":8201,"date":"2015-01-30T11:03:12","date_gmt":"2015-01-30T13:03:12","guid":{"rendered":"http:\/\/treetech.com.br\/en\/articles\/others\/monitoracao-on-line-de-transformadores-conversores-do-sistema-de-transmissao-hvdc-na-se-ibiuna"},"modified":"2016-10-24T16:53:07","modified_gmt":"2016-10-24T18:53:07","slug":"online-monitoring-of-converter-transformers-of-ss-ibiuna-hvdc-transmission-system","status":"publish","type":"post","link":"https:\/\/treetech.com.br\/en\/online-monitoring-of-converter-transformers-of-ss-ibiuna-hvdc-transmission-system\/","title":{"rendered":"Online monitoring of converter transformers of SS Ibi\u00fana HVDC transmission system"},"content":{"rendered":"<div class=\"wpb-content-wrapper\">[vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]\n<h1><strong>Abstract<\/strong><\/h1>\n<p>The relevance of Ibi\u00fana Converter Substation for the supply of electricity to S\u00e3o Paulo led Furnas to select the online monitoring of converter transformers, initially by replacing mechanical temperature measurement systems with electronic monitors and subsequently with the complete monitoring of one of the converter transformers. This document provides installation details and in-field experiences concerning the online monitoring, including data transmission of transformer sensors via wireless network using Wi-Fi technology.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;5095&#8243; img_size=&#8221;thumbnail&#8221; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div><style>.vcex-button.vcex_69d0c3ee7d5ac{background:#b2b2b2;color:#ffffff!important;}.vcex-button.vcex_69d0c3ee7d5ac:hover{background:#008242!important;}<\/style><div class=\"theme-button-wrap textcenter theme-button-block-wrap wpex-block wpex-clear wpex-clr\"><a href=\"http:\/\/treetech.com.br\/wp-content\/uploads\/2016\/10\/XIIIEriac_Furnas_Ibiuna_MonitoracaoTrafoConversor_2009_eng.pdf\" class=\"vcex-button theme-button flat grey medium align-center block vcex_69d0c3ee7d5ac\" title=\"Download\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"vcex-button-inner theme-button-inner wpex-flex wpex-flex-wrap wpex-items-center wpex-justify-center\"><span class=\"vcex-button-icon vcex-icon-wrap theme-button-icon-left\"><span class=\"wpex-icon\" aria-hidden=\"true\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M64 464l48 0 0 48-48 0c-35.3 0-64-28.7-64-64L0 64C0 28.7 28.7 0 64 0L229.5 0c17 0 33.3 6.7 45.3 18.7l90.5 90.5c12 12 18.7 28.3 18.7 45.3L384 304l-48 0 0-144-80 0c-17.7 0-32-14.3-32-32l0-80L64 48c-8.8 0-16 7.2-16 16l0 384c0 8.8 7.2 16 16 16zM176 352l32 0c30.9 0 56 25.1 56 56s-25.1 56-56 56l-16 0 0 32c0 8.8-7.2 16-16 16s-16-7.2-16-16l0-48 0-80c0-8.8 7.2-16 16-16zm32 80c13.3 0 24-10.7 24-24s-10.7-24-24-24l-16 0 0 48 16 0zm96-80l32 0c26.5 0 48 21.5 48 48l0 64c0 26.5-21.5 48-48 48l-32 0c-8.8 0-16-7.2-16-16l0-128c0-8.8 7.2-16 16-16zm32 128c8.8 0 16-7.2 16-16l0-64c0-8.8-7.2-16-16-16l-16 0 0 96 16 0zm80-112c0-8.8 7.2-16 16-16l48 0c8.8 0 16 7.2 16 16s-7.2 16-16 16l-32 0 0 32 32 0c8.8 0 16 7.2 16 16s-7.2 16-16 16l-32 0 0 48c0 8.8-7.2 16-16 16s-16-7.2-16-16l0-64 0-64z\"\/><\/svg><\/span><\/span>Download<span class=\"vcex-button-icon vcex-icon-wrap theme-button-icon-right\"><span class=\"wpex-icon\" aria-hidden=\"true\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M288 32c0-17.7-14.3-32-32-32s-32 14.3-32 32V274.7l-73.4-73.4c-12.5-12.5-32.8-12.5-45.3 0s-12.5 32.8 0 45.3l128 128c12.5 12.5 32.8 12.5 45.3 0l128-128c12.5-12.5 12.5-32.8 0-45.3s-32.8-12.5-45.3 0L288 274.7V32zM64 352c-35.3 0-64 28.7-64 64v32c0 35.3 28.7 64 64 64H448c35.3 0 64-28.7 64-64V416c0-35.3-28.7-64-64-64H346.5l-45.3 45.3c-25 25-65.5 25-90.5 0L165.5 352H64zm368 56a24 24 0 1 1 0 48 24 24 0 1 1 0-48z\"\/><\/svg><\/span><\/span><\/span><\/a><\/div> [\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\" style=\"height:10px;\"><\/div>[vc_accordion][vc_accordion_tab title=&#8221;Authors&#8221;][vc_column_text]\n<table class=\" alignleft\" style=\"color: #7e7c7c; height: 121px;\" width=\"443\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td class=\"td_item\" style=\"font-weight: bold; text-align: left;\">Furnas Centrais El\u00e9tricas S.A.<\/td>\n<td>E. G. Peres<\/td>\n<\/tr>\n<tr>\n<td class=\"td_item\" style=\"font-weight: bold; text-align: left;\">Furnas Centrais El\u00e9tricas S.A.<\/td>\n<td>W. R. Duso<\/td>\n<\/tr>\n<tr>\n<td class=\"td_item\" style=\"font-weight: bold; text-align: left;\">Furnas Centrais El\u00e9tricas S.A.<\/td>\n<td>J. S. Latenek<\/td>\n<\/tr>\n<tr>\n<td class=\"td_item\" style=\"font-weight: bold; text-align: left;\">Treetech Sistemas Digitais Ltda.<\/td>\n<td>M. E. G. Alves<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/vc_column_text][\/vc_accordion_tab][\/vc_accordion][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=&#8221;1.0 &#8211; INTRODUCTION&#8221; element_type=&#8221;div&#8221; span_color=&#8221;#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Ibi\u00fana is the substation where the converter terminal of Itaipu high-voltage direct current transmission system (HVDC) is located, i.e., Ibi\u00fana substation is the terminal where direct current is turned into alternating current (345kV 60Hz) to supply Greater S\u00e3o Paulo.<\/p>\n<p>This system, transmitting at \u00b1600kVdc half of Itaipu generating capacity (6,300 MW), is comprised of 8 converters, each 2 converters forming a pole and each 2 poles forming a bipole. The substation has 24 converter transformers in operation with installed capacity of 7,200MVA.<\/p>\n<p>Ibi\u00fana converter transformers are single-phase units, each having two primary windings and one secondary winding. Because they are 12-pulse converters, transformer primary windings should be fed by two three-phase systems 30\u00ba out of phase between each other. For such, one of the primary windings of single-phase units of each bank is star connected, and the other primary winding is delta connected. The three-line diagram in figure 1 shows this topology for bipole 1 pole 2 containing converters 2 and 4, which is fed at +600kVdc. Pole 1 of the same bipole has identical configuration, except that it is fed at -600kVdc.<\/p>\n<p>Each transformer has two on-load tap-changers (OLTC) that are driven by a common motorized mechanism, given that the operation should be simultaneous. The automatic control system enables the OLTC when valve firing angles exceed the rated operating range. Figure 2 shows an overview of a single-phase converter transformer.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=&#8221;8193&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Fig. 1 &#8211; Three-line Diagram of Converter Pole<\/strong><\/em><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=&#8221;8194&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Fig. 2 &#8211; Single-phase converter transformer overview<\/strong><\/em><\/p>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=&#8221;2.0 &#8211; CONVERTER TRANSFORMER ONLINE MONITORING&#8221; element_type=&#8221;div&#8221; span_color=&#8221;#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]The critical relevance of these transformers for Brazilian electricity system, combined with the unique, harsh working conditions which they are subject to, such as the high content of voltage harmonics, led Furnas to implement online monitoring on these machines performed in two main stages, as described next.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=&#8221;2.1 &#8211; Temperature Monitoring Upgrade&#8221; element_type=&#8221;h2&#8243; span_background=&#8221;#008242&#8243; span_color=&#8221;#008242&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]In the first stage of online monitoring implementation the temperature supervision systems of all 24 converter transformers were upgraded, by replacing all oil thermometers and original, mechanical windings with digital temperature monitors, as figure 3 illustrates.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;8196&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;8195&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<p style=\"text-align: center;\"><strong><em>Fig. 3 &#8211; Converter transformer temperature monitoring upgrade (a) Beginning of original mechanical thermometer replacement; (b) Digital temperature monitors installed.<\/em><\/strong><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]One of the purposes of this stage was to reduce the failure rate of oil temperature measurement system and windings, already obsolete, and remove the need for periodic calibration of these components. Additionally, upgrading the temperature supervision system provided several new functionalities:<\/p>\n<ul>\n<li>Redundant measurement of oil top temperature, increasing measurement safety and allowing continued operation in case one sensor fails.<\/li>\n<li>Winding template calculated by mathematical model &#8211; enhanced accuracy without the use of heating resistance for simulation;<\/li>\n<li>Possibility of measuring additional temperatures such as ambient and on-load tap-changer temperatures;<\/li>\n<li>Self-calibration of measurements;<\/li>\n<li>Output contacts for alarms, switch-off and cooling commands with timing;<\/li>\n<li>Current outputs for remote indications of integrated temperatures &#8211; removing transducers;<\/li>\n<li>Cooling command on manual or automatic mode;<\/li>\n<li>Automatic switchover of forced cooling groups;<\/li>\n<li>Transformer pre-cooling in case of load current increase;<\/li>\n<li>Automatic daily drills of cooling groups;<\/li>\n<li>Mass memory for measurements and events;<\/li>\n<li>As an option, monitoring of OLTC temperature differential for fault diagnosis.<\/li>\n<li>Serial communication ports for integration to remote systems.<\/li>\n<\/ul>\n<p>This latter functionality &#8211; serial communication ports &#8211; specially opens the possibility of integrating the temperature monitors to an Online Monitoring software, so that the measurements taken by the equipment may be used by mathematical algorithms for transformer status diagnosis. Figure 4 illustrates this application, which indicates that algorithms may be implemented in the monitoring software based on information sent by the Temperature Monitor.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_row_inner][vc_column_inner][vc_single_image image=&#8221;8185&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]\n<p style=\"text-align: center;\"><strong><em>Fig. 4 &#8211; Temperature Monitor serial communication port integration to a transformer Online Monitoring software and possible diagnosis algorithms.<\/em><\/strong><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]To run the Online Monitoring software a server was installed in the substation control room, which is connected to transformer Temperature Monitor serial ports. Initially, the physical media used for this connection were shielded twisted-pair cables. Later, in order to render network installation easier and reduce its costs, Wi-Fi wireless communication was used, which is now in operation with fully satisfactory results despite the high level of electromagnetic interference in this substation. Figure 5 shows the components for wireless communication.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8188&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8186&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;8187&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Fig. 5 &#8211; Monitoring System Communication Components. (a) Wi-Fi communication module installed next to temperature monitors and other sensors on transformer body; (b) Tower next to control room where the Access Point was installed for communication with transformer sensors; (c) Access Point detail with antenna and view towards the substation.<\/strong><\/em><\/p>\n[\/vc_column_text][vc_row_inner][vc_column_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]\n<p style=\"text-align: left;\">To ensure secure access to the Wi-Fi network MAC addresses filtering was implemented in the Access Point, so that only with previously registered MAC are able to be connected. As additional measure, WEP data encryption was used.<\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=&#8221;2.2 &#8211; Online Monitoring of Converter 4 Transformers&#8221; element_type=&#8221;div&#8221; span_background=&#8221;#008242&#8243; span_color=&#8221;#008242&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]One of the main features of the monitoring system implemented in SS Ibi\u00fana is its modular design, allowing that new monitoring functions or even new equipment to be easily added. Leveraging on this feature, the second implantation stage of online monitoring for transformers was comprised of adding several sensors to Converter 4, as well as corresponding monitoring software modules. Table I below lists the sensors installed and their corresponding functions, including the existing Temperature Monitor in this transformer.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_row_inner][vc_column_inner][vc_column_text]\n<p style=\"text-align: center;\"><span id=\"tablepress-197-description\" class=\"tablepress-table-description tablepress-table-description-id-197\">Sensors installed on converter 4 transformer, their corresponding measurements and local independent functionalities<\/span>\n\n<table id=\"tablepress-197\" class=\"tablepress tablepress-id-197\" aria-describedby=\"tablepress-197-description\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><strong>Sensor<\/strong><\/th><th class=\"column-2\"><strong>Measurementes Performed<\/strong><\/th><th class=\"column-3\"><strong>Local Independent Functions<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">TM1 and TM2 Temperature Monitors<\/td><td class=\"column-2\">- Oil Temperature;<br \/>\n- Temperature of hottest point in Windings<br \/>\n- Load current<\/td><td class=\"column-3\">- Alarm and switch-off by Oil temperature<br \/>\n- Alarm and switch-off by Winding temperature<br \/>\n- Forced Cooling automatic and manual control<br \/>\n- Transformer pre-cooling by load increase<br \/>\n- Daily fan drills<br \/>\n- On-Load Tap-Changer temperature differential<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">BM Bushing Monitor<\/td><td class=\"column-2\">- Bushing capacitance<br \/>\n- Bushing delta tangent<\/td><td class=\"column-3\">- Capacitance upward trend<br \/>\n- Delta Tangent upward trend<br \/>\n- Time for High\/Very High Capacitance Alarms <br \/>\n- Time for High\/Very High Delta Tangent Alarms<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Dissolved Gas-in-Oil Monitor<\/td><td class=\"column-2\">- Content of dissolved hydrogen in transformer oil (ppm)<br \/>\n- Oil temperature at hydrogen measurement point<\/td><td class=\"column-3\">- Content of hydrogen in oil upward trend<br \/>\n- High or Very High hydrogen in oil alarms<br \/>\n- High H2 in oil upward trend alarms<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">DM1\/DM2 signal Digitalization Modules<\/td><td class=\"column-2\">- Measurement of alarm dry contact state<br \/>\n- Measurement of transformer oil level<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">OLTC Oil Humidity Monitor<\/td><td class=\"column-2\">- Relative saturation (%) of water in oil<br \/>\n- Content of water in oil (ppm)<br \/>\n- Oil temperature<\/td><td class=\"column-3\">- Content of water in oil upward trend<br \/>\n- High or Very High water in oil saturation (%) alarms<br \/>\n- High or Very High Content of water in oil alarms<br \/>\n- High water Content upward trend alarms<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Transformer Oil Humidity Monitor<\/td><td class=\"column-2\">- Relative saturation (%) of water in oil<br \/>\n- Content of water in oil (ppm)<br \/>\n- Ambient temperature <br \/>\n- Oil temperature<\/td><td class=\"column-3\">- Content of water in oil upward trend<br \/>\n- High or Very High water in oil saturation (%) alarms<br \/>\n- High or Very High Content of water in oil alarms<br \/>\n- High water Content upward trend alarms<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Bag Rupture Relay<\/td><td class=\"column-2\">- Expansion tank bag rupture<\/td><td class=\"column-3\">- Bag Rupture Alarm<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">DTM Temperature Monitor<\/td><td class=\"column-2\">- Oil Temperature at heat exchanger inlets<br \/>\n- Oil Temperature at heat exchanger outlets<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">PI Position Indicator<\/td><td class=\"column-2\">- On-Load Tap-Changer tap position<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]\n<p style=\"text-align: left;\">Based on the measurements of the sensors above, the monitoring software uses the following Engineering Modules shown in table II for data processing, so as to provide to user diagnostics and prognostics of transformer state.<\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]\n<p style=\"text-align: center;\"><span id=\"tablepress-200-description\" class=\"tablepress-table-description tablepress-table-description-id-200\">Engineering modules for transformer state diagnostics and prognostics<\/span>\n\n<table id=\"tablepress-200\" class=\"tablepress tablepress-id-200\" aria-describedby=\"tablepress-200-description\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><strong>Engineering Modules<\/strong><\/th><th class=\"column-2\"><strong>Diagnostics and Prognostics Performed<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Insulation Aging<\/td><td class=\"column-2\">\u2022\tLoss of Insulation Service Life<br \/>\n\u2022\tLoss of service life rate<br \/>\n\u2022\tRemaining service life prediction, in years<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Future Temperature Forecast<\/td><td class=\"column-2\">\u2022\tWinding temperature after thermal stability<br \/>\n\u2022\tForecast of alarm and switch-off events<br \/>\n\u2022\tCalculation of remaining time for alarm and switch-off events.<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Cooling Efficiency<\/td><td class=\"column-2\">\u2022\tCalculation of expected oil temperature according to load, ambient temperature and operating cooling group<br \/>\n\u2022\tComparison with actual temperature measured and alarm in case of cooling low performance - measured temperature way above the expected<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Cooling Group Maintenance<\/td><td class=\"column-2\">\u2022\tCooling group running hours since start up<br \/>\n\u2022\tCooling group running hours since last maintenance<br \/>\n\u2022\tCooling average daily running hours<br \/>\n\u2022\tPrediction of remaining time for inspection or maintenance<br \/>\n\u2022\tAdvance warning for inspection or maintenance.<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Water in Oil and in Paper<\/td><td class=\"column-2\">\u2022\tContent of water in Oil<br \/>\n\u2022\tContent of water in Paper<br \/>\n\u2022\tAcceleration of loss of insulation service life by excess of water<br \/>\n\u2022\tBubble Formation Temperature by excess of water<br \/>\n\u2022\tFree Water Formation Temperature by excess of water in oil<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">OLTC Temperature Differential<\/td><td class=\"column-2\">\u2022\tTap-changer instantaneous temperature differential<br \/>\n\u2022\tTap-changer filtrate temperature differential<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Chromatography<\/td><td class=\"column-2\">\u2022\tOnline measurement of dissolved hydrogen in oil<br \/>\n\u2022\tHigh, very high or upward trend H2 content alarm<br \/>\n\u2022\tOffline gas chromatography analysis database<br \/>\n\u2022\tCalculation of gas increase rates<br \/>\n\u2022\tReports for gas chromatography analysis according to IEC60599 and Duval<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Physical-chemical<\/td><td class=\"column-2\">\u2022\tOffline physical-chemical tests in oil database<br \/>\n\u2022\tAutomatic reports according to NBR10576<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_text_separator title=&#8221;3.0 &#8211; FIELD EXPERIENCE WITH ONLINE MONITORING&#8221; element_type=&#8221;div&#8221; span_color=&#8221;#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]The first installation stage of converter transformer monitoring system, covering the replacement of mechanical thermometers with Temperature Monitors, was performed from 2006 to 2007. The second installation stage, in which remaining sensors were added for complete Converter 4 monitoring, was performed in July\/2008.<\/p>\n<p>Figure 6 shows some details of sensor installation and necessary adjustments for such, as transformers were constructed in the 1980&#8217;s and were not prepared for that. In general, the installation was successful as sensors are operating as expected after start up.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=&#8221;8189&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][vc_column_text]\n<p style=\"text-align: center;\"><strong><em>Fig. 6 &#8211; In-field installation of Monitoring sensors. (a) Panel with monitoring equipment and ambient temperature sensor; (b) Oil temperature sensor at heat exchanger inlet and outlet; (c) Gas and oil humidity sensors on transformer; (d) Connections to bushing taps; (e) OLTC oil humidity and temperature sensors; (f) Redundant temperature sensors for oil top; (g) Ladder burst sensor; (h) Ladder burst relay.<\/em><\/strong><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text]Following commissioning, the monitoring system started recording the measurements in database, as shown in the example of figure 7, where a chart shows oil and winding temperatures and contents of water in transformer oil and on-load tap-changer oil.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=&#8221;8190&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][vc_column_text]\n<p style=\"text-align: center;\"><strong><em>Fig. 7 &#8211; Examples of measurements recorded in history database<\/em><\/strong><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Because of the large geographical area covered by Furnas, as well as the large number of transformers used, one of the main requirements for a monitoring system is the remote access to information. To allow this access from any point within its facilities, the existing Intranet network in the company was the communication means selected.<\/p>\n<p>For that, the monitoring server located in the control room is connected to the In order with access to data, information, diagnostics and prognostics performed from any computer in the company network.<\/p>\n<p>In addition, with transformers in normal operating conditions, which is expected most of the time, the monitoring system will remain in static condition only eventually issuing a fault diagnosis.<\/p>\n<p>To remove the need for ongoing system tracking, which would consume a great deal of time of the maintenance team, the monitoring system was equipped with an automatic email sending device in case any abnormality is found. For that, the email addresses of people who should be warned must be previously registered in the system.<\/p>\n<p>Figure 8 below shows some examples of typical screens with online measurements and diagnosis of the monitoring system.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=&#8221;8191&#8243; alignment=&#8221;center&#8221; onclick=&#8221;img_link_large&#8221;][vc_column_text]\n<p style=\"text-align: center;\"><strong><em>Fig. 8 &#8211; Typical monitoring system diagnosis screen<\/em><\/strong><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=&#8221;4.0 &#8211; CONCLUSIONS&#8221; element_type=&#8221;div&#8221; span_color=&#8221;#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Experiences with the implementation of online monitoring and their practical outcomes achieved concerning HVDC Converter Transformers have been allowing to assess the benefits and effectiveness of the decentralized architecture of sensors, communication means and software solutions used, as well as the ruggedness of the electronic equipment installed in SE Ibi\u00fana, which have been showing satisfactory results.<\/p>\n<p>We may highlights the following benefits provided by the monitoring system installed:<\/p>\n<ul>\n<li>Elimination of costly and time-consuming annual thermometer calibration procedures;<\/li>\n<li>Extension of transformer service life by fast detection of conditions that could cause accelerated degrading, such as conservator tank ladder burst;<\/li>\n<li>Reduced risks of catastrophic failures through, for example, online monitoring of hydrogen in oil;<\/li>\n<li>Increased equipment availability for the electrical system due to reduced preventive maintenance shutdowns, for example, for bushing tests;<\/li>\n<li>As a result, reduced maintenance costs and, eventually, insurance costs and others.<\/li>\n<\/ul>\n<p>Given that the application of HVDC technology for electricity transmission from other hydropower projects in the north of the country is under consideration, the experience with the implementation of online monitoring for SE Ibi\u00fana converter transformers could be highly valuable to enhance reliability and full performance of these new applications.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=&#8221;5.0 &#8211; REFERENCES&#8221; element_type=&#8221;div&#8221; span_color=&#8221;#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text][1]\u00a0\u00a0 Albuquerque, Roberto, Alves, Marcos, \u201cMonitora\u00e7\u00e3o On-Line de um Banco de Autotransformadores 345-138\/13,8kV 150MVA com Comuta\u00e7\u00e3o Sob Carga\u201d, XIX SNPTEE \u2013 Semin\u00e1rio Nacional de Produ\u00e7\u00e3o e Transmiss\u00e3o de Energia El\u00e9trica. Rio de Janeiro, Brasil, 2007.<\/p>\n[2]\u00a0\u00a0 Melo, Marcos A. C., Alves, Marcos, \u201cExperi\u00eancia com Monitora\u00e7\u00e3o On-Line de Capacit\u00e2ncia e Tangente Delta de Buchas Condensivas\u201d, XIX SNPTEE \u2013 Semin\u00e1rio Nacional de Produ\u00e7\u00e3o e Transmiss\u00e3o de Energia El\u00e9trica. Rio de Janeiro, Brasil, 2007.<\/p>\n[3]\u00a0\u00a0 Alves, Marcos, Ara\u00fajo, Daniel C. P., Martins, Alvaro J. A. L., Costa, Marcelo A., \u201cMonitora\u00e7\u00e3o e Diagn\u00f3stico On-Line de Transformador de Pot\u00eancia com \u00d3leo Vegetal\u201d, V Workspot \u2013 Workshop on Power Transformers, Bel\u00e9m, Brasil, 2008.<\/p>\n[4]\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Alves, Marcos, Silva, Gilson, \u201cExperi\u00eancia de Campo com Monitora\u00e7\u00e3o On-Line de um Transformador 343MVA 230kV com 2 Comutadores sob Carga\u201d, IV Workspot \u2013 Workshop on Power Transformers, Recife, Brasil, 2005.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] Abstract The relevance of Ibi\u00fana Converter Substation for the supply of electricity to S\u00e3o Paulo led Furnas to select the online monitoring of converter transformers, initially by replacing mechanical temperature measurement systems with electronic monitors and subsequently with the complete monitoring of one of the converter transformers. This document provides installation details and&hellip;<\/p>\n","protected":false},"author":1,"featured_media":8089,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[139],"tags":[],"class_list":["post-8201","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-transmission","entry","has-media"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/posts\/8201","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/comments?post=8201"}],"version-history":[{"count":0,"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/posts\/8201\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/media\/8089"}],"wp:attachment":[{"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/media?parent=8201"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/categories?post=8201"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/treetech.com.br\/en\/wp-json\/wp\/v2\/tags?post=8201"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}