{"id":8226,"date":"2015-01-19T21:40:22","date_gmt":"2015-01-19T23:40:22","guid":{"rendered":"http:\/\/treetech.com.br\/es\/articulos\/otros\/relatorio-tecnico-testes-comparativos-entre-monitor-on-line-de-umidade-mo-treetech-e-analise-de-teor-de-agua-por-karl-fischer"},"modified":"2022-04-18T14:49:09","modified_gmt":"2022-04-18T17:49:09","slug":"informe-tecnico-pruebas-comparativas-entre-monitor-online-de-humedad-mo-de-treetech-y-analisis-de-contenido-de-agua-por-karl-fischer","status":"publish","type":"post","link":"https:\/\/treetech.com.br\/es\/informe-tecnico-pruebas-comparativas-entre-monitor-online-de-humedad-mo-de-treetech-y-analisis-de-contenido-de-agua-por-karl-fischer\/","title":{"rendered":"Informe T\u00e9cnico \u2013 Pruebas comparativas entre Monitor Online de Humedad MO de Treetech y an\u00e1lisis de contenido de agua por Karl Fischer"},"content":{"rendered":"<div class=\"wpb-content-wrapper\">[vc_row][vc_column width=\u00bb2\/3&#8243;][vc_column_text]\n<h1><strong>Resumen<\/strong><\/h1>\n<p>Este informe presenta los datos obtenidos con la aplicaci\u00f3n de dos Monitores de Humedad MO en una m\u00e1quina de secado de aceite en la subestaci\u00f3n Tatu\u00ed de Elektro. Presenta tambi\u00e9n la comparaci\u00f3n entre las mediciones online de esos equipos y los an\u00e1lisis de contenido de agua a trav\u00e9s del m\u00e9todo de Kart Fischer. Para ello, el equipo de laboratorio fue llevado a la referida subestaci\u00f3n el d\u00eda 05\/04\/2007, permitiendo la comparaci\u00f3n directa entre los resultados online y los de laboratorio con reducido riesgo de contaminaci\u00f3n de las muestras de aceite.[\/vc_column_text][\/vc_column][vc_column width=\u00bb1\/3&#8243;][vc_single_image image=\u00bb5143&#8243; img_size=\u00bbthumbnail\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb]<div class=\"vcex-spacing wpex-w-100 wpex-clear\" style=\"height:10px;\"><\/div><style>.vcex-button.vcex_69da2604bcb10{background:#b2b2b2;color:#ffffff!important;}.vcex-button.vcex_69da2604bcb10:hover{background:#008242!important;}<\/style><div class=\"theme-button-wrap textcenter theme-button-block-wrap wpex-block wpex-clear wpex-clr\"><a href=\"http:\/\/treetech.com.br\/wp-content\/uploads\/2016\/02\/Elektro_Tatui_AnaliseMO_2007_esp.pdf\" class=\"vcex-button theme-button flat grey medium align-center block vcex_69da2604bcb10\" title=\"Download\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"vcex-button-inner theme-button-inner wpex-flex wpex-flex-wrap wpex-items-center wpex-justify-center\"><span class=\"vcex-button-icon vcex-icon-wrap theme-button-icon-left\"><span class=\"wpex-icon\" aria-hidden=\"true\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M64 464l48 0 0 48-48 0c-35.3 0-64-28.7-64-64L0 64C0 28.7 28.7 0 64 0L229.5 0c17 0 33.3 6.7 45.3 18.7l90.5 90.5c12 12 18.7 28.3 18.7 45.3L384 304l-48 0 0-144-80 0c-17.7 0-32-14.3-32-32l0-80L64 48c-8.8 0-16 7.2-16 16l0 384c0 8.8 7.2 16 16 16zM176 352l32 0c30.9 0 56 25.1 56 56s-25.1 56-56 56l-16 0 0 32c0 8.8-7.2 16-16 16s-16-7.2-16-16l0-48 0-80c0-8.8 7.2-16 16-16zm32 80c13.3 0 24-10.7 24-24s-10.7-24-24-24l-16 0 0 48 16 0zm96-80l32 0c26.5 0 48 21.5 48 48l0 64c0 26.5-21.5 48-48 48l-32 0c-8.8 0-16-7.2-16-16l0-128c0-8.8 7.2-16 16-16zm32 128c8.8 0 16-7.2 16-16l0-64c0-8.8-7.2-16-16-16l-16 0 0 96 16 0zm80-112c0-8.8 7.2-16 16-16l48 0c8.8 0 16 7.2 16 16s-7.2 16-16 16l-32 0 0 32 32 0c8.8 0 16 7.2 16 16s-7.2 16-16 16l-32 0 0 48c0 8.8-7.2 16-16 16s-16-7.2-16-16l0-64 0-64z\"\/><\/svg><\/span><\/span>Download<span class=\"vcex-button-icon vcex-icon-wrap theme-button-icon-right\"><span class=\"wpex-icon\" aria-hidden=\"true\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M288 32c0-17.7-14.3-32-32-32s-32 14.3-32 32V274.7l-73.4-73.4c-12.5-12.5-32.8-12.5-45.3 0s-12.5 32.8 0 45.3l128 128c12.5 12.5 32.8 12.5 45.3 0l128-128c12.5-12.5 12.5-32.8 0-45.3s-32.8-12.5-45.3 0L288 274.7V32zM64 352c-35.3 0-64 28.7-64 64v32c0 35.3 28.7 64 64 64H448c35.3 0 64-28.7 64-64V416c0-35.3-28.7-64-64-64H346.5l-45.3 45.3c-25 25-65.5 25-90.5 0L165.5 352H64zm368 56a24 24 0 1 1 0 48 24 24 0 1 1 0-48z\"\/><\/svg><\/span><\/span><\/span><\/a><\/div> [\/vc_column][\/vc_row][vc_row][vc_column width=\u00bb2\/3&#8243;][vc_accordion][vc_accordion_tab title=\u00bbAutor\u00bb][vc_column_text]\n<table class=\" alignleft\" style=\"color: #7e7c7c; height: 121px;\" width=\"443\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td class=\"td_item\" style=\"font-weight: bold; text-align: left;\">Treetech Sistemas Digitais Ltda.<\/td>\n<td>Marcos E. G. Alves<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n[\/vc_column_text][\/vc_accordion_tab][\/vc_accordion][\/vc_column][vc_column width=\u00bb1\/3&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_text_separator title=\u00bb1.0 &#8211; CONFIGURACI\u00d3N DE LA INSTALACI\u00d3N\u00bb element_type=\u00bbdiv\u00bb span_color=\u00bb#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]La configuraci\u00f3n de la instalaci\u00f3n es mostrada en la figura 1, donde se observa la m\u00e1quina de secado de aceite en l\u00ednea modelo Zeon acoplada a un transformador de potencia 10\/12.5 MVA 138\/13.8 kV llenado con aceite aislante mineral.<\/p>\n<p>El aceite sale del transformador por su v\u00e1lvula de drenado inferior, que est\u00e1 conectada a la entrada de la m\u00e1quina a trav\u00e9s de tubos flexibles con paredes dobles. Luego de entrar en la m\u00e1quina, el aceite pasa por el sensor del monitor de humedad online modelo MO de Treetech, pasando enseguida por una bomba de circulaci\u00f3n de aceite y por los elementos absorbedores, que retienen el agua dejando pasar el aceite. El flujo prosigue entonces para la salida de la m\u00e1quina, donde pasa por el segundo monitor de humedad MO y retorna al transformador a trav\u00e9s de una v\u00e1lvula en la parte inferior del tanque conservador.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_row_inner][vc_column_inner width=\u00bb1\/3&#8243;][vc_single_image image=\u00bb8213&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/3&#8243;][vc_single_image image=\u00bb8214&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/3&#8243;][vc_single_image image=\u00bb8215&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][\/vc_column_inner][\/vc_row_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\" style=\"height:15px;\"><\/div>[vc_row_inner][vc_column_inner width=\u00bb1\/2&#8243;][vc_single_image image=\u00bb8216&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][\/vc_column_inner][vc_column_inner width=\u00bb1\/2&#8243;][vc_single_image image=\u00bb8217&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Figura 1 \u2013 Configuraci\u00f3n de la instalaci\u00f3n; a) M\u00e1quina de secado Zeon; b) Sensor MO en la entrada de la m\u00e1quina; c) Sensor MO en la salida; d) M\u00f3dulos de interfaz; e) Medidor de contenido de agua Metrohm.<\/strong><\/em><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]A su vez, los Monitores de Humedad MO 1 y 2 est\u00e1n conectados a un modem GPRS a trav\u00e9s de sus puertas de comunicaci\u00f3n serial RS-485, permitiendo as\u00ed la lectura remota online del contenido de agua en el aceite que entra y que sale de la m\u00e1quina de secado. El acceso remoto permite tambi\u00e9n el download de datos en la memoria de masa de los monitores de humedad, tornando posible el seguimiento de la evoluci\u00f3n del proceso de secado del aceite y el monitoreo del estado de los elementos absorbedores, que deben ser substituidos cuando se saturan en agua.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb2.0 &#8211; ENSAYOS REALIZADOS\u00bb element_type=\u00bbh2&#8243; span_background=\u00bb#008242&#8243; span_color=\u00bb#008242&#8243;][\/vc_column][\/vc_row][vc_row][vc_column]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]La configuraci\u00f3n descrita arriba, con un sensor de humedad recibiendo aceite m\u00e1s h\u00famedo en la entrada de la m\u00e1quina de secado y un sensor en la salida recibiendo aceite m\u00e1s seco, permite que se efect\u00fae la comparaci\u00f3n de las mediciones online con los resultados de laboratorio en por lo menos dos diferentes situaciones de contenido de agua en el aceite. Para eso, fue instalado en una oficina de la subestaci\u00f3n un medidor de contenido de agua marca Metrohm, del laboratorio MGM Diagn\u00f3sticos Ltda. De esa forma, las diversas muestras retiradas en el flujo de aceite en la entrada y en la salida de la m\u00e1quina de secado eran inmediatamente analizadas en el equipo Metrohm, permitiendo determinar sus contenidos de agua con bajo riesgo de contaminaci\u00f3n de las muestras con humedad debido al tiempo transcurrido en el transporte.<\/p>\n<p>&nbsp;<\/p>\n<p>La secuencia de las pruebas realizadas es presentada en las tablas 1 y 2 para los monitores de humedad 1 y 2, respectivamente. Al final de esos ensayos fueron retiradas dos muestras de aceite adicionales, ambas en la salida de la m\u00e1quina de secado, donde se encuentran los menores contenidos de agua. Una de esas muestras fue ensayada en el laboratorio 3 horas m\u00e1s tarde en el mismo d\u00eda. La otra muestra fue ensayada 4 d\u00edas despu\u00e9s, el d\u00eda 09\/4. Los contenidos de agua obtenidos fueron 2,5ppm para la muestra ensayada en el mismo d\u00eda y 2,7ppm y 2,8ppm 4 d\u00edas m\u00e1s tarde.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_row_inner][vc_column_inner][vc_column_text]\n<p style=\"text-align: center;\"><span id=\"tablepress-204-description\" class=\"tablepress-table-description tablepress-table-description-id-204\">Monitor de Humedad MO 1<\/span>\n\n<table id=\"tablepress-204\" class=\"tablepress tablepress-id-204 tbody-has-connected-cells\" aria-describedby=\"tablepress-204-description\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><strong>Hora<\/strong><\/th><th class=\"column-2\"><strong>Lab (ppm)<\/strong><\/th><th class=\"column-3\"><strong>MO (ppm)<\/strong><\/th><th class=\"column-4\"><strong>Temp del aceite (\u00b0C)<\/strong><\/th><th class=\"column-5\"><strong>MO (RS%)<\/strong><\/th><th class=\"column-6\"><strong>Muestra<\/strong><\/th><th class=\"column-7\"><strong>Observaciones<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">10:15<\/td><td class=\"column-2\">2,1<\/td><td class=\"column-3\">0,4<\/td><td class=\"column-4\">26,4<\/td><td class=\"column-5\">0,5<\/td><td class=\"column-6\">1<\/td><td rowspan=\"2\" class=\"column-7\">Muestra retirada en la salida de la m\u00e1quina, en su interior<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">10:19<\/td><td class=\"column-2\">2,3<\/td><td class=\"column-3\">0,4<\/td><td class=\"column-4\">26,4<\/td><td class=\"column-5\">0,5<\/td><td class=\"column-6\">1<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">10:37<\/td><td colspan=\"5\" class=\"column-2\">Sensor desplazado 10 mm, alejado del flujo de aceite<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">10:52<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,6<\/td><td class=\"column-4\">31,4<\/td><td class=\"column-5\">0,7<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">10:52<\/td><td colspan=\"5\" class=\"column-2\">Sensor desplazado 20 mm, alejado del flujo de aceite<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">11:02<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,5<\/td><td class=\"column-4\">31,6<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">11:03<\/td><td colspan=\"5\" class=\"column-2\">Sensor retornado a la posici\u00f3n original<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">11:05<\/td><td class=\"column-2\">1,9<\/td><td class=\"column-3\">0,3<\/td><td class=\"column-4\">32,4<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\">3<\/td><td rowspan=\"2\" class=\"column-7\">Muestra de la salida de la m\u00e1quina en el tanque de expansi\u00f3n<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">11:07<\/td><td class=\"column-2\">1,9<\/td><td class=\"column-3\">0,3<\/td><td class=\"column-4\">32,4<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\">3<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">11:27<\/td><td colspan=\"5\" class=\"column-2\">Bomba de aceite desconectada<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">11:27<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,2<\/td><td class=\"column-4\">32<\/td><td class=\"column-5\">0,2<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">11:34<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,3<\/td><td class=\"column-4\">31,8<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">11:46<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,6<\/td><td class=\"column-4\">31<\/td><td class=\"column-5\">0,7<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">11:47<\/td><td colspan=\"5\" class=\"column-2\">Bomba de aceite reconectada<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">11:47<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,6<\/td><td class=\"column-4\">31,2<\/td><td class=\"column-5\">0,7<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">11:50<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,3<\/td><td class=\"column-4\">32<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">13:40<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,3<\/td><td class=\"column-4\">39,1<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">13:53<\/td><td colspan=\"5\" class=\"column-2\">Sensor movido hacia la entrada de la m\u00e1quina de secado<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">13:55<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">8<\/td><td class=\"column-4\">38,7<\/td><td class=\"column-5\">7<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">13:57<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">8<\/td><td class=\"column-4\">38,6<\/td><td class=\"column-5\">6,8<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">14:00<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">7,8<\/td><td class=\"column-4\">38,4<\/td><td class=\"column-5\">7<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-204 from cache -->\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]\n<p style=\"text-align: center;\"><span id=\"tablepress-207-description\" class=\"tablepress-table-description tablepress-table-description-id-207\">Monitor de Humedad MO 2<\/span>\n\n<table id=\"tablepress-207\" class=\"tablepress tablepress-id-207 tbody-has-connected-cells\" aria-describedby=\"tablepress-207-description\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><strong>Hora<\/strong><\/th><th class=\"column-2\"><strong>Lab (ppm)<\/strong><\/th><th class=\"column-3\"><strong>MO (ppm)<\/strong><\/th><th class=\"column-4\"><strong>Temp del Aceite (\u00b0C)<\/strong><\/th><th class=\"column-5\"><strong>MO (RS%)<\/strong><\/th><th class=\"column-6\"><strong>N\u00famero de Muestra<\/strong><\/th><th class=\"column-7\"><strong>Observaciones<\/strong<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">10:30<\/td><td class=\"column-2\">8,8<\/td><td class=\"column-3\">6,4<\/td><td class=\"column-4\">33,7<\/td><td class=\"column-5\">6,7<\/td><td class=\"column-6\">2<\/td><td rowspan=\"2\" class=\"column-7\">Muestra de la entrada de la m\u00e1quina, en la salida del transformador<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">10:32<\/td><td class=\"column-2\">8,8<\/td><td class=\"column-3\">6,4<\/td><td class=\"column-4\">33,7<\/td><td class=\"column-5\">6,7<\/td><td class=\"column-6\">2<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">11:20<\/td><td class=\"column-2\">7,3<\/td><td class=\"column-3\">6,5<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\">4<\/td><td rowspan=\"3\" class=\"column-7\">Muestra de la entrada de la m\u00e1quina, en la salida del transformador<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">11:22<\/td><td class=\"column-2\">8,3<\/td><td class=\"column-3\">6,5<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\">4<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">11:25<\/td><td class=\"column-2\">8,7<\/td><td class=\"column-3\">6,5<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\">4<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">11:27<\/td><td colspan=\"5\" class=\"column-2\">Bomba de aceite desconectada<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">11:27<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">6,5<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">11:34<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">7,5<\/td><td class=\"column-4\">32,4<\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">11:46<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">7,6<\/td><td class=\"column-4\">31<\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">11:47<\/td><td colspan=\"5\" class=\"column-2\">Bomba de aceite reconectada<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">11:47<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">7<\/td><td class=\"column-4\">33,3<\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">11:50<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">6,9<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">13:40<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">7<\/td><td class=\"column-4\">38,7<\/td><td class=\"column-5\">6,1<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">13:53<\/td><td colspan=\"5\" class=\"column-2\">Sensor movido hacia la salida de la m\u00e1quina de secado<\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">13:55<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">2,7<\/td><td class=\"column-4\">38,1<\/td><td class=\"column-5\">1,9<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">13:57<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">1<\/td><td class=\"column-4\">37,9<\/td><td class=\"column-5\">0,8<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">14:00<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">0,4<\/td><td class=\"column-4\">37,5<\/td><td class=\"column-5\">0,3<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-207 from cache -->\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.0 &#8211; AN\u00c1LISIS DE LOS RESULTADOS\u00bb element_type=\u00bbdiv\u00bb span_color=\u00bb#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.1 &#8211; Repetibilidad y estabilidad de las mediciones\u00bb element_type=\u00bbdiv\u00bb span_color=\u00bb#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]El gr\u00e1fico de la figura 2 permite la comparaci\u00f3n visual entre las mediciones online a lo largo de los ensayos y los resultados obtenidos por el m\u00e9todo de Karl Fischer. En ese gr\u00e1fico se observa una buena correlaci\u00f3n entre ambos m\u00e9todos.<\/p>\n<p>Tambi\u00e9n la repetibilidad de las mediciones es comprobada a trav\u00e9s de la inversi\u00f3n de los sensores, cuando el sensor originalmente localizado en la entrada de la m\u00e1quina (aceite m\u00e1s h\u00famedo) fue cambiado hacia la salida (aceite m\u00e1s seco) y viceversa.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=\u00bb8218&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Figura 2 \u2013 Mediciones de contenido de agua online y de laboratorio<\/strong><\/em><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]A partir del gr\u00e1fico de la figura 2 se puede concluir que la medici\u00f3n online present\u00f3 gran estabilidad, ya que no fue influenciada por factores relacionados con la retirada, el manejo y procesamiento de muestras, como ocurre con las mediciones en laboratorio. Ese hecho puede ser constatado observ\u00e1ndose que, mientras las mediciones online en la entrada de la m\u00e1quina permanecieron estables en torno de 6,5ppm desde las 10:30 a las 11:30h, las mediciones de laboratorio presentaron variaci\u00f3n de hasta 1,5ppm, iniciando con 8,8, reduci\u00e9ndose a 7,3 y retornando a 8,7ppm.[\/vc_column_text][vc_row_inner][vc_column_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.2 &#8211; Tiempo de respuesta del sensor de humedad online\u00bb element_type=\u00bbdiv\u00bb span_background=\u00bb#008242&#8243; span_color=\u00bb#008242&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]La inversi\u00f3n de los sensores efectuada durante las pruebas permiti\u00f3 cuantificar el tiempo de respuesta de los sensores online a un cambio de grado en el contenido de agua. Tomando las mediciones del sensor que fue movido de la entrada (mayor contenido de agua) para la salida de la m\u00e1quina (menor contenido de agua), se observa que la medici\u00f3n pas\u00f3 de su valor inicial de 7ppm a las 13:53h hasta el valor final de 0,4ppm a las 14:00h.<\/p>\n<p>Con ello, el sensor respondi\u00f3 completamente al grado de cambio del contenido de agua en aproximadamente 7 minutos, inferior, por lo tanto, a su tiempo de respuesta nominal de 15 minutos.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.3 &#8211; Influencia del tiempo transcurrido luego del muestreo en las mediciones de laboratorio\u00bb element_type=\u00bbdiv\u00bb span_background=\u00bb#008242&#8243; span_color=\u00bb#008242&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Las mediciones de contenido de agua en las muestras transportadas para an\u00e1lisis posterior en el laboratorio no demostraron variaci\u00f3n significativa en relaci\u00f3n con las mediciones realizadas con el mismo equipo en la subestaci\u00f3n, tanto para el an\u00e1lisis realizado en el mismo d\u00eda como luego de 4 d\u00edas.<\/p>\n<p>Ese resultado confirma que, una vez que el proceso de muestreo es realizado correctamente y con equipo adecuado, las muestras pueden ser transportadas y almacenadas durante algunos d\u00edas sin alteraciones en los resultados.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.4 &#8211; Influencia del flujo de aceite en las mediciones online\u00bb element_type=\u00bbdiv\u00bb span_background=\u00bb#008242&#8243; span_color=\u00bb#008242&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]La influencia de la velocidad del flujo de aceite en las mediciones online fue verificada desconectando y reconectando la bomba de aceite. El resultado puede ser observado en el gr\u00e1fico de la figura 2, donde se verifica una elevaci\u00f3n de 1ppm en la medici\u00f3n online de la entrada de la m\u00e1quina cuando la bomba es desconectada, y una reducci\u00f3n de 0,5ppm al ser restablecido el flujo de aceite. La peque\u00f1a magnitud de las alteraciones contactadas indica que el efecto del flujo de aceite en las mediciones puede ser desconsiderado, a\u00fan cuando sea posible eliminarlo completamente por la inclusi\u00f3n de una protecci\u00f3n en el conjunto sensor.<\/p>\n<p>En la salida de la m\u00e1quina, con contenido de agua reducido, la influencia del flujo en la medici\u00f3n fue a\u00fan menor, del orden de 0,3ppm.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.5 &#8211; Comparaci\u00f3n entre mediciones online y lecturas de laboratorio\u00bb element_type=\u00bbdiv\u00bb span_background=\u00bb#008242&#8243; span_color=\u00bb#008242&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Las comparaciones entre las mediciones online y las de laboratorio, considerando los l\u00edmites de error de cada proceso \u2013 +\/- 1,7ppm a 30\u00b0C para la medici\u00f3n online y +\/- 2ppm para la medici\u00f3n de laboratorio \u2013 son mostradas en los gr\u00e1ficos de la figura 3 para la entrada y salida de la m\u00e1quina de secado. Las l\u00edneas intermitentes arriba y abajo de cada medici\u00f3n indican, respectivamente, los valores de tolerancia superior e inferior de la medici\u00f3n, obtenidos sumando y substrayendo la medici\u00f3n o su l\u00edmite de error.<\/p>\n<p>En esos gr\u00e1ficos se observa visualmente la existencia de una gran \u00e1rea de intersecci\u00f3n entre las mediciones online y las de laboratorio. Tanto en la salida como en la entrada de la m\u00e1quina de secado, el l\u00edmite de tolerancia superior de la medici\u00f3n online llega a alcanzar la medici\u00f3n de laboratorio, y el l\u00edmite de tolerancia inferior y la medici\u00f3n de laboratorio llegan a alcanzar la medici\u00f3n online. Queda comprobado, por lo tanto, que las diferencias verificadas entre las mediciones online y de laboratorio no superan los l\u00edmites de error de ambos m\u00e9todos.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_single_image image=\u00bb8206&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb]<div class=\"vcex-spacing wpex-w-100 wpex-clear\" style=\"height:15px;\"><\/div>[vc_single_image image=\u00bb8208&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][vc_row_inner][vc_column_inner][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Figura 3 \u2013 Tolerancias superior e inferior de las mediciones de contenido de agua online y de laboratorio<\/strong><\/em><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_text_separator title=\u00bb3.6 &#8211; Correlaci\u00f3n entre mediciones online y de laboratorio\u00bb element_type=\u00bbdiv\u00bb span_color=\u00bb#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]La correlaci\u00f3n entre los dos m\u00e9todos de medici\u00f3n puede ser m\u00e1s f\u00e1cilmente visualizada a partir del gr\u00e1fico de la figura 4, en el cual son mostradas las mediciones <i>online<\/i> (eje vertical) en funci\u00f3n de las mediciones en laboratorio (eje horizontal).[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_single_image image=\u00bb8210&#8243; alignment=\u00bbcenter\u00bb onclick=\u00bbimg_link_large\u00bb][vc_column_text]\n<p style=\"text-align: center;\"><em><strong>Figura 4 \u2013 Mediciones de contenido de agua online en funci\u00f3n de las mediciones de laboratorio<\/strong><\/em><\/p>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Fue determinada, a trav\u00e9s de los m\u00ednimos cuadrados, la ecuaci\u00f3n que mejor relaciona los datos de mediciones de los dos m\u00e9todos, consider\u00e1ndose una relaci\u00f3n de 1<sup>er<\/sup> grado:<\/p>\n<p style=\"text-align: center;\"><em>(H2O Online) = 0,9462 * (H2O Laboratorio) \u2013 1,5226<\/em><\/p>\n<p>A partir de esa ecuaci\u00f3n, mostrada en l\u00ednea intermitente en el gr\u00e1fico de la figura 4, se constata, asumiendo que las mediciones de laboratorio corresponden a la realidad del contenido de agua presente en el aceite, que:<\/p>\n<p>1) La medici\u00f3n online responde a las variaciones del contenido de agua en el aceite de forma pr\u00e1cticamente ideal, como demuestra el factor de proporcionalidad muy cercano a uno (0,9462);<\/p>\n<p>2) La medici\u00f3n online present\u00f3 un desplazamiento (offset) de aproximadamente 1,5ppm en relaci\u00f3n con el contenido de agua de la muestra, como muestra la constante independiente de la ecuaci\u00f3n (-1,5226).<\/p>\n<p>A partir de esas dos constantes, se constata que la diferencia anteriormente observada entre las mediciones online y de laboratorio, a\u00fan dentro de los rangos de tolerancia de ambos m\u00e9todos, es causada principalmente por un error de desplazamiento (offset), del orden de 1,5ppm.<\/p>\n<p>Aunque la diferencia entre las mediciones de laboratorio y online se encuentra dentro de los l\u00edmites de error de los dos m\u00e9todos, y la respuesta a las variaciones en el contenido de agua en el aceite no sea afectada por ese desplazamiento, el mismo puede ser compensado, si deseado, con peque\u00f1as alteraciones en el ajuste de offset del monitor de humedad online.<\/p>\n<p>Para probar ese tipo de ajuste, el mismo fue efectuado tras la finalizaci\u00f3n de las pruebas, alter\u00e1ndose el par\u00e1metro offset del sensor de la entrada de la m\u00e1quina de 0,785 a 0,738 y el de la salida de 0,797 a 0,750. Con ello, las mediciones online se alteraron para 9,6ppm y 1,5ppm, respectivamente, m\u00e1s pr\u00f3ximas a los valores obtenidos con el equipo de laboratorio.[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_text_separator title=\u00bb4.0 &#8211; CONCLUSIONES\u00bb element_type=\u00bbdiv\u00bb span_color=\u00bb#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]Los resultados de los ensayos descritos permiten arribar a las siguientes conclusiones:<\/p>\n<ul>\n<li>El monitor de humedad online MO es capaz de indicar de forma eficaz la ocurrencia de alteraciones en la humedad del aceite, ya que responde a las variaciones del contenido de agua en el aceite de forma pr\u00e1cticamente ideal, o sea, con factor de proporcionalidad muy cercano a 1 (uno).<\/li>\n<li>La buena respuesta a variaciones en el contenido de agua del aceite fue comprobada tambi\u00e9n a partir de pruebas con el cambio del sensor de la entrada de la m\u00e1quina para la salida y viceversa, provocando as\u00ed cambios de grado en los contenidos de agua en el aceite.<\/li>\n<li>La prueba de cambio de posici\u00f3n de los sensores demostr\u00f3 tambi\u00e9n la repetibilidad de las mediciones online, que no sufrieron alteraciones significativas a\u00fan despu\u00e9s del cambio de los sensores.<\/li>\n<li>A trav\u00e9s de la prueba de cambio de posici\u00f3n de los sensores fue verificado tambi\u00e9n el tiempo de respuesta a variaciones en el contenido de agua, que fue del orden de 7 minutos.<\/li>\n<li>La comparaci\u00f3n entre las mediciones online y de laboratorio demostr\u00f3 que las diferencias observadas no superan los l\u00edmites de error de ambos m\u00e9todos.<\/li>\n<li>A trav\u00e9s de correlaci\u00f3n entre las mediciones online y de laboratorio se constat\u00f3 que la diferencia entre ambas es causada principalmente por un error de desplazamiento (offset), del orden de 1,5ppm.<\/li>\n<li>Aunque la diferencia entre las mediciones de laboratorio y online se encuentra dentro de los l\u00edmites de error de los dos m\u00e9todos, y la respuesta a las variaciones en el contenido de agua en el aceite no sea afectada por ese desplazamiento, el mismo puede ser compensado con peque\u00f1as alteraciones en el ajuste de offset del monitor de humedad online.<\/li>\n<\/ul>\n[\/vc_column_text]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_text_separator title=\u00bbAGRADECIMIENTOS\u00bb element_type=\u00bbdiv\u00bb span_color=\u00bb#008842&#8243;]<div class=\"vcex-spacing wpex-w-100 wpex-clear\"><\/div>[vc_column_text]La realizaci\u00f3n de las pruebas y la elaboraci\u00f3n de este informe solamente fueron posibles con la colaboraci\u00f3n de diversas personas y empresas. Nuestros agradecimientos a:<\/p>\n<ul>\n<li>Elektro Servi\u00e7os de Eletricidade S.A. \u2013 Ings. Jos\u00e9 Daniel Eurico, Adriano Cabrino y equipo regional de Tatu\u00ed, por el soporte para la realizaci\u00f3n de las pruebas durante el proceso de secado de uno de los transformadores de la SE Tatu\u00ed.<\/li>\n<li>MGM Diagn\u00f3sticos SA \u2013 Ing. Cl\u00e1udio Galdeano, por el soporte y la consultor\u00eda t\u00e9cnica en todo el proceso y por la cesi\u00f3n del equipo de medici\u00f3n de contenido de agua en el aceite y del t\u00e9cnico para la realizaci\u00f3n de los an\u00e1lisis en campo.<\/li>\n<li>Henrique Hossri \u2013 por el soporte y la consultor\u00eda t\u00e9cnica en todo el proceso y auxilio en la retirada de muestras de aceite y manipulaci\u00f3n de los sensores.<\/li>\n<\/ul>\n[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=\u00bb2\/3&#8243;][vc_column_text] Resumen Este informe presenta los datos obtenidos con la aplicaci\u00f3n de dos Monitores de Humedad MO en una m\u00e1quina de secado de aceite en la subestaci\u00f3n Tatu\u00ed de Elektro. Presenta tambi\u00e9n la comparaci\u00f3n entre las mediciones online de esos equipos y los an\u00e1lisis de contenido de agua a trav\u00e9s del m\u00e9todo de Kart&hellip;<\/p>\n","protected":false},"author":1,"featured_media":4925,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[133],"tags":[],"class_list":["post-8226","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-distribucion","entry","has-media"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/posts\/8226","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/comments?post=8226"}],"version-history":[{"count":0,"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/posts\/8226\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/media\/4925"}],"wp:attachment":[{"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/media?parent=8226"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/categories?post=8226"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/treetech.com.br\/es\/wp-json\/wp\/v2\/tags?post=8226"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}